Compliance cases
These are the 7,246 inputs a submission must answer.
A conforming implementation returns true
for the 2,791 valid ones and false
for the 4,455 invalid ones.
You can run the suite without reading it, or open any case to see its input and where its first ill-formed byte is.
Well-formed means Table 3-7 of the Unicode Standard, as RFC 3629 restates it: no overlong forms, surrogates, code points above U+10FFFF, stray continuation bytes or sequences cut short. The compliance suite combines Markus Kuhn's UTF-8 stress test, WPT's fatal TextDecoder tests, every lead byte against the edges of its allowed ranges, errors at every offset around 16-, 32- and 64-byte blocks and at the end of every length up to 130 bytes, large inputs, and seeded random text. simdutf, Python and a Table 3-7 reference agree on every answer.
Run the full compliance suite locally. Replace your-component.wasm
with your compiled component.
Download the suite
curl -fLo validate_utf8.comply.wasm https://calculated.world/comply/validate_utf8.wasm
npx qipok your-component.wasm --suite validate_utf8.comply.wasm
450 of 7,246 cases · 0 true · 450 false
| Case | Name | Expected | Note | Size |
|---|---|---|---|---|
| 000278 | regression/single byte B3 Focused regression | false | 1 B | |
| 000279 | regression/single byte B4 Focused regression | false | 1 B | |
| 000280 | regression/single byte B5 Focused regression | false | 1 B | |
| 000281 | regression/single byte B6 Focused regression | false | 1 B | |
| 000282 | regression/single byte B7 Focused regression | false | 1 B | |
| 000283 | regression/single byte B8 Focused regression | false | 1 B | |
| 000284 | regression/single byte B9 Focused regression | false | 1 B | |
| 000285 | regression/single byte BA Focused regression | false | 1 B | |
| 000286 | regression/single byte BB Focused regression | false | 1 B | |
| 000287 | regression/single byte BC Focused regression | false | 1 B | |
| 000288 | regression/single byte BD Focused regression | false | 1 B | |
| 000289 | regression/single byte BE Focused regression | false | 1 B | |
| 001947 | regression/64 continuation bytes after U+20AC Focused regression | false | 67 B | |
| 001948 | regression/4096 continuation bytes Focused regression | false | 4.0 KiB | |
| 002404 | regression/stray 80 at 0 in ASCII Focused regression | false | 128 B | |
| 002405 | regression/stray 80 at 1 in ASCII Focused regression | false | 128 B | |
| 002406 | regression/stray 80 at 12 in ASCII Focused regression | false | 128 B | |
| 002407 | regression/stray 80 at 13 in ASCII Focused regression | false | 128 B | |
| 002408 | regression/stray 80 at 14 in ASCII Focused regression | false | 128 B | |
| 002409 | regression/stray 80 at 15 in ASCII Focused regression | false | 128 B | |
| 002410 | regression/stray 80 at 16 in ASCII Focused regression | false | 128 B | |
| 002411 | regression/stray 80 at 17 in ASCII Focused regression | false | 128 B | |
| 002412 | regression/stray 80 at 28 in ASCII Focused regression | false | 128 B | |
| 002413 | regression/stray 80 at 29 in ASCII Focused regression | false | 128 B | |
| 002414 | regression/stray 80 at 30 in ASCII Focused regression | false | 128 B | |
| 002415 | regression/stray 80 at 31 in ASCII Focused regression | false | 128 B | |
| 002416 | regression/stray 80 at 32 in ASCII Focused regression | false | 128 B | |
| 002417 | regression/stray 80 at 33 in ASCII Focused regression | false | 128 B | |
| 002418 | regression/stray 80 at 44 in ASCII Focused regression | false | 128 B | |
| 002419 | regression/stray 80 at 45 in ASCII Focused regression | false | 128 B | |
| 002420 | regression/stray 80 at 46 in ASCII Focused regression | false | 128 B | |
| 002421 | regression/stray 80 at 47 in ASCII Focused regression | false | 128 B | |
| 002422 | regression/stray 80 at 48 in ASCII Focused regression | false | 128 B | |
| 002423 | regression/stray 80 at 49 in ASCII Focused regression | false | 128 B | |
| 002424 | regression/stray 80 at 60 in ASCII Focused regression | false | 128 B | |
| 002425 | regression/stray 80 at 61 in ASCII Focused regression | false | 128 B | |
| 002426 | regression/stray 80 at 62 in ASCII Focused regression | false | 128 B | |
| 002427 | regression/stray 80 at 63 in ASCII Focused regression | false | 128 B | |
| 002428 | regression/stray 80 at 64 in ASCII Focused regression | false | 128 B | |
| 002429 | regression/stray 80 at 65 in ASCII Focused regression | false | 128 B | |
| 002430 | regression/stray 80 at 76 in ASCII Focused regression | false | 128 B | |
| 002431 | regression/stray 80 at 77 in ASCII Focused regression | false | 128 B | |
| 002432 | regression/stray 80 at 78 in ASCII Focused regression | false | 128 B | |
| 002433 | regression/stray 80 at 79 in ASCII Focused regression | false | 128 B | |
| 002434 | regression/stray 80 at 80 in ASCII Focused regression | false | 128 B | |
| 002435 | regression/stray 80 at 81 in ASCII Focused regression | false | 128 B | |
| 002436 | regression/stray 80 at 92 in ASCII Focused regression | false | 128 B | |
| 002437 | regression/stray 80 at 93 in ASCII Focused regression | false | 128 B | |
| 002438 | regression/stray 80 at 94 in ASCII Focused regression | false | 128 B | |
| 002439 | regression/stray 80 at 95 in ASCII Focused regression | false | 128 B |
Where these rules come from
Well-formed UTF-8 is defined by Table 3-7 of
the Unicode Standard, chapter 3
, which
RFC 3629
restates as ABNF. Every answer is agreed by
simdutf
9.4.0, Python’s strict codec and a direct reading of the table; the
suite’s own tests add Node.js’s buffer.isUtf8
and a fatal TextDecoder.
- UTF-8 decoder capability and stress test — Markus Kuhn’s file, the source of the 80 Kuhn cases
-
WPT textdecoder-fatal tests
— what browsers must reject when decoding with
fatal: true - Validating UTF-8 In Less Than One Instruction Per Byte — John Keiser and Daniel Lemire’s vectorised algorithm, which simdutf uses